ADLINK Technology cPCI-9116 Guide de l'utilisateur Page 54

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 67
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 53
44 Operation Theory
(M_Counter=M=2, DIV_Counter=4, SC_Counter=N=2)
Acquisition_in_progress
Scan_start
AD_conversion
Scan_in_progress
(SSH_OUT)(pin47)
Acquired data
Acquired & stored data
(M+N scans)
Trigger occurs when a scan is in progress
Operation start
ExtTrg(pin46)
M scans before
trigger
N scans
after trigger
Figure 15: Middle trigger (trigger with scan is in progress)
Post-Trigger Acquisition
Use post-trigger acquisition in applications where you want to collect data after
an external trigger event. The number of scans after the trigger is specified in
SC_counter, as illustrated in fig 16. The total acquired data length =
DIV_counter *SC_counter.
(DIV_Counter=4, SC_Counter=3)
Acquisition_in_progress
Scan_start
AD_conversion
Scan_in_progress
(SSH_OUT)
Acquired & stored data
(3 scans)
Operation start
ExtTrg
Figure 16: Post trigger
Vue de la page 53
1 2 ... 49 50 51 52 53 54 55 56 57 58 59 ... 66 67

Commentaires sur ces manuels

Pas de commentaire