32 Registers
EOC_en (bit8): End of conversion Interrupt Enable Control
1: Enable
0: Disable
Clr_Timer (bit4): write 1 to clear the GPTC Interrupt status
1: clear interrupt from the GPTC
0: no effect
Clr_SCTC (bit3): write 1 to clear the SCTC Interrupt
1: clear the interrupt on terminal count of the Scan
counter
0: no effect
Clr_HFull (bit2): write 1 to clear the data FIFO half full interrupt
1: clear the interrupt on the data FIFO half full status
0: no effect
Clr_DTrg (bit1): write 1 to clear the Digital Trigger Interrupt
1: clear the interrupt when trigger happens
0: no effect
Clr_EOC (bit0): write 1 to clear the End of Conversion Interrupt
1: clear the interrupt when EOC
0: no effect