ADLINK Technology PCI-8136M Guide de l'utilisateur Page 37

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 107
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 36
Signal Connection 29
3.7 Emergency stop signal ESTOP
The emergency stop signal ESTOP is used to stop pulse output from all OUT
and DIR channels. The following is the ping assignment information for
ESTOP.
Signal Name
CN 1 Pin No.
Description Alternative Name
COM+ 6 Ext +24V COM+
COM+ 7 Ext +24V COM+
COM+ 8 Ext +24V COM+
ESTOP 57 Emergency stop signal
DI 19
COM- 55 Ext Common Ground
COM-
COM- 56 Ext Common Ground
COM-
Notice that the alternative name means that if users don’t use motion
functions at one or more axes, the digital input will be treated as general
purpose input channel.
The input circuit of alarm circuit is shown in the following diagram. The
external circuit must provide at least 6 mA current sink capability to drive the
ESTOP signal active.
Figure 3.7.1 Connection of ESTOP